FGR3-C Known Issues and Resolution
Issue:
In the FGR3-C firmware version 11.00.11 (Initial Release):
- Signal and Noise values reported from the firmware in hexadecimal format (0-F) instead of decimal
- Noise value reported as an instantaneous value resulting in volatility
-
- The above issues would cause Diagnostics values to trigger Warning and Alarm Alerts.
- Additionally we released the attached Product Advisory back in December 2019 clarifying that Tool Suite must be updated to prevent disabling the hidden unit specific Transmit Power Calibration value.
Resolution:
Use Tool Suite version 2.13.2 (or newer) to upgrade the FGR3-C firmware to version 11.00.13 (example screen shot below)
Optimal product behavior of FGR2-C Product Series and FGR3-C Firmware version 11.00.13 (available in Tool Suite version 2.13.2):
- Signal and Noise reported in decimal format (0-9)
- Noise reported from the firmware as an averaged value.
Support Knowledge Base Articles:
Product Advisory - Using-Tool-Suite-with-FGR3s-SI-15
FGR3-CE-C-Serial-Radios
Comments